OKIMAT IPS

The modern double drive with integrated SMPS, for easy tool-free fitting. Meets the eco-design directive (standby power consumption <0.5 W). Integrated mains socket and plug-in mains cable as an option.

  • Load capacity: max. 6000 N on each side (for safety reasons, no pull force)
  • Adjustment speed: max. 4.5 mm/sec. *
  • Equipment options: additional control options (e.g. two OKIMAT in parallel controllable with one handset), 2.4 GHz radio control, emergency lowering via 9 V battery

 

* depending on drive configuration at constant 24/29 V without load

Standard configurations

Performance data
Load capacity max. 6000 N on each side (for safety reasons, no pull force)
Adjustment speed 1 max. 4.5 mm/sec.
Stroke length back rest: 87 mm
leg rest: 69 mm
Fitting dimension installation length: 708 mm
component height: 120 mm
axle distance: 581 mm (+/- 2 mm)
axle diameter: 25 mm
Duty cycle 2/18 min. or 10 %, max. 5 switching cycles per minute
Control unit relay-free control, relay circuit
Motor voltage maintenance-free 24V DC motor
Components
Limit switch with micro switch
Housing colour black RAL 9005, grey RAL 7035
Supply cable EURO-plug, black RAL 9017, straight, 2000 mm
SMPS integrated SMPS
Further data
Connectivity 2 1 handset or 1 handheld transmitter
Protection type IP20
Protection class II
Relative humidity 30% – 75%
Ambient temperature +10°C - +40°C
Power supply wide input voltage range 100-240 V AC

Extra configurations

Performance data
Fitting dimension axis diameter: 34 mm
Further data
Quick release /
Retracting function 3
emergency lowering via 9 V battery
Equipment options additional control options (e.g. two OKIMAT in parallel controllable with one handset), 2.4 GHz radio control

1 depending on the drive configuration and the control components which are used
2 (example, depending on control unit type)
3 Retracting function: The clutch of the lowering function must be open during the entire downward movement.

Manuals
Ident No. Title Language Type  
78433 OKIMAT IPS D Installation instruction  
78434 OKIMAT IPS GB Installation instruction  
70195 OKIMAT RF D Quick guide  
70196 OKIMAT RF GB Quick guide  
Flyer
Title Language  
OKIMAT IPS GB  

DatasheetRequest 3D cad data: Please contact an office next to you

Note: Responsibility for OKIN products when used for specific applications and for adherence to the appropriate guidelines, standards and laws is borne by the manufacturer of the complete system into which OKIN products are fitted. We accept no liability for the correctness.

CE declaration of conformity:
We herewith declare that the actuator described above complies with the basic requirements of EC Guideline 2014/30/EU and EC Guideline 2014/35/EU in terms of its conception and design as well as the version we have placed into circulation. We would be glad to help you in having your end products inspected by certified testing companies such as TÜV, LGA, UL, JET, LNE etc.